skip to main content | skip to footer
N.C. Department of Environment and Natural Resources

NC Department of Environment and Natural Resources
Water Quality - Collection Systems

Water Quality

Web Content Display Web Content Display

Collection Systems

Any references to the 15A NCAC 2H .0200 rules will be overridden by the new 2T Rules. Rule Highlights:

  • Sewer extensions are mainly covered under 2T .0300.
  • System-wide Collection System Permitting is covered under 2T .0400.
  • The available power reliability option for pump stations can no longer be wet well storage for waters near Class C. Stations over 15,000 gallons per day require a permanent generator and those under require a portable generator receptacle. All stations now require telemetry/auto-dialer in addition to audible and visual alarms.
  • For developer permitted projects, a copy of the Declarations must be submitted with the final engineering certification to demonstrate compliance with the terms of the Operational Agreement.
  • More flow rates have been included in 2T .0114.
  • Change of ownerships for private permitted projects (i.e. developer to homeowner association or public utility) must be submitted at the time of final certification.
  • The separation distance between storm sewers and sanitary sewers has been increased to 24 inches unless structural bridging is provided.
  • Separation distances between reclaimed water lines and wetlands and sanitary sewers has been added to 2T .0300.

 

 

Documents and Files

 

38364 FEEDBACK

Your input is valuable to us. Please send us your feedback.

What type of feedback would you like to send?*

Ask a Question Report a Problem Have a Concern Make a Comment

(If you would like us to respond please include your phone or e-mail.)

Your Question has been sent. Thank you!

An internal server error prevented Your Question from being sent.
Please try again later, or call Toll-Free (877) 623-6748 for immediate assistance.

Please complete all highlighted items

Your Problem has been sent. Thank you!

An internal server error prevented Your Question from being sent.
Please try again later, or call Toll-Free (877) 623-6748 for immediate assistance.

Please complete all highlighted items

Your Concern has been sent. Thank you!

An internal server error prevented Your Question from being sent.
Please try again later, or call Toll-Free (877) 623-6748 for immediate assistance.

Please complete all highlighted items

Your Comment has been sent. Thank you!

An internal server error prevented Your Question from being sent.
Please try again later, or call Toll-Free (877) 623-6748 for immediate assistance.

Please complete all highlighted items

*If you are a DENR employee with an I.T. issue, please submit a DOTS ticket.